1.6. Weight
ROLLER'S Multi-Control SL
ROLLER'S Multi-Control SLW
1.7. Noise information
Work place-related
Emission value
2. Start-up
CAUTION
Transport weights above 35 kg must be carried by at least 2 persons.

2.1. Electrical connection

WARNING
Caution: Mains voltage present! Before connecting the electronic flushing and 
pressure testing unit, check whether the voltage given on the rating plate corre-
sponds to the mains voltage. Only use sockets/extension leads with a functioning
PE contact. The function of the PRCD fault current circuit breaker (Fig. 1 (1))
must be checked every time before start-up and before beginning work:
1. Plug the mains plug into the socket.
2. Press the RESET button (2), the PRCD control lamp (Fig. 1 (39)) lights red
(operating state).
3. Pull out the mains plug, the PRCD control lamp (39) must go out.
4. Plug the mains plug back into the socket.
5. Press the RESET button (2), the PRCD control lamp (39) lights red (oper-
ating state).
6. Press the TEST button (3), the PRCD control lamp (39) must go out.
7. Press the RESET button (2) again, the PRCD control lamp (39) lights red.
The control lamp (Fig. 2 (5)) lights green. ROLLER'S Multi-Control is ready
for operation after about 10 s.
WARNING
If the described functions of the PRCD fault current circuit breaker (Fig. 1 (1))
are not fulfilled, the device may not be used. There is a danger of electric shock. 
The PRCD fault current circuit breaker tests the connected device, not the
installation before the socket nor interconnected extension leads or cable reels.
On building sites, in a wet environment, indoors and outdoors or under similar
installation conditions, only operate the electronic flushing and pressure testing 
unit on the mains with a fault current protection switch (FI switch) which interrupts
the power supply as soon as the leakage current to earth exceeds 30 mA for
200 ms. A cable cross-section that corresponds to the power of the electronic
flushing and pressure testing unit must be selected when using an extension 
lead.
Press the On/Off button on the input and control unit's operating panel (Fig. 2
(4)) for approx. 2 s, then release it. ROLLER'S Multi-Control is switched on and
the compressor switches on. The screen (6) is illuminated and the ROLLER'S
Multi-Control logo appears followed by the start menu:
Flushing
Disinfection
Testing
Compressed Air Pump
Memory Manager
2.2. Menu structure and on-screen displays
Five main programs of the ROLLER'S Multi-Control are displayed in the Start
menu: Flushing, Disinfection, Testing, Compressed Air Pump, Memory Manager.
The screen display contains a maximum 5 lines with 20 characters each. Lines
with defaults or test values are displayed language-independently with phys-
ical formula symbols, a uniform verbal abbreviation and the value of the test
criterion in the sub-routines. These have the following meanings:
p refer
bar xxx
reference test pressure bar
p refer
mbar xxx
reference test pressure mbar
p actual bar xxx
actual test pressure
p actual mbar xxx
actual test pressure
p diff
bar xxx
differential test pressure bar
p diff
mbar xxx
differential test pressure mbar
t stabi
min xxx
stabilisation/wait time
t test
min xxx
test time
Δ > 10K   
difference >10°C (10 Kelvin) water/environment
PfS 
press fitting system (ZVSHK)
P+M
load test plastic + metal
p H
O
bar
water pressure
2
v H
O 
m/s 
minimum flow speed
2
t H
O 
min 
flushing time
2
n H
O
n-times
water change
2
VA H
O l
volume of the flushing section
2
VS H
O  l/min 
volume flow
2
V H
O
l
used water volume
2
File no.
memory location no. for measuring log
max. DN
largest rated diameter
Enter
next screen display
Esc
previous screen display or cancel
Ver. Software
version software
36.7 kg (81 lb)
39.0 kg (86 lb)
L
= 73 dB(A); L
= 92 dB(A); K = ± 1 dB
PA
WA
bar
mbar
min
min
2.3. Settings menu
NOTICE
The defaults for the different test criteria in the settings menu of the ROLLER'S
Multi-Control are taken from EN 806-4:2010 or the information leaflet "Leak 
tests of drinking water installations with compressed air, inert gas or water"
(January 2011) of the German Central Association for Sanitary, Heating and
Air Conditioning (ZVSHK). All defaults for the test programs can be edited by
the user in the Settings menu and in the Flushing, Test with compressed air,
Test with water and Compressed Air Pump programs. Changes in the Settings
menu are saved, i.e. they reappear the next time the ROLLER'S Multi-Control
is switched on. If the defaults are only changed in one of the programs, the
original defaults appear again the next time the ROLLER'S Multi-Control is
switched on. Reset resets all defaults to factory settings and the language to
German and the date, time, units formats to DD.MM.YYYY, 24 h, m / bar.
Attention: The user is solely responsible for transferred or newly entered
test criteria (test sequences, pressures and times) or defaults in the
individual programs and the conclusions from the tests.
The respective national safety provisions, rules and regulations valid for
the application site must be considered and observed.
Before using the ROLLER'S Multi-Control, check whether the respective latest
version software is installed on the input and control unit. Select the Settings
menu and then Device data to display the version software. The latest version
software (Ver. Software) for the input and control unit is available by USB stick
as a download: www.albert-roller.de → Downloads → Software → ROLLER'S 
Multi-Control → Download. Compare the number of the version software of the
unit with the latest version software number and install the latest version soft-
ware if necessary.
Download procedure:
1.  Download file
2.  Unpack the ZIP file
3. Save "update.bin" on USB stick
4. Plug the USB stick into the USB port of the ROLLER'S Multi-Control
ROLLER'S Multi-Control must be switched off for this, switch off with the On/
Off button (Fig. 2 (4)) and pull out the mains plug if necessary. Insert the USB
stick with the latest version software into the USB port (Fig. 2 (33)). Plug the
mains plug into the socket. Press the Reset button (Fig. 1 (2)) of the PRCD
fault current circuit breaker (1). The control lamp (5) lights green. The latest
version software is installed. When a USB stick with LED is used, the LED
starts flashing. The installation is finished when the LED no longer flashes. If 
the USB stick has no LED, you should wait about 1 minute after switching on
the PRCD. The latest version software is then installed on the input and control
unit. Pull out the USB stick.
Before starting up for the first time, the language, date and time should be set 
in the Settings menu and the defaults for the individual programs checked and
changed if necessary.
If the "?" button (Fig. 2 (7)) is pressed within 5 s after switching on the ROLLER'S
Multi-Control, the Settings menu opens. The desired line is selected on the
screen with the arrow buttons ↑ ↓ (8). Displayed values can be changed with 
the arrow buttons ← → (11). The value is increased with the arrow pointing to 
the right and reduced with the arrow pointing to the left. The values change
faster when the arrow buttons ← → (11) are kept pressed. If more than 5 lines 
in a subroutine are occupied, this is displayed by arrows ▼▲ in the top or 
bottom right hand corner of the screen respectively. The complete selection of
the screen is confirmed with the Enter button (9) and the next screen appears.
The previous screen appears if the Esc button (10) is pressed during the setting.
Already changed values are rejected.
If the Esc button (10) is pressed during the stabilisation/wait time (t stabi), the
program aborts, the values (useless) are still saved, appear on the screen and
"Cancel" appears additionally on the screen and possibly on the print strip.
If the Esc button (10) is pressed during the test time (t test), the values are still
saved, appear on the screen and "Cancel" appears additionally on the screen
and possibly on the print strip. In the test programs Enter provides a shortcut
for the adaptation of p actual to p refer.
Select language, Enter:
Default German (deu) is preselected. Another language can be selected with
the arrow buttons ← → (11), press Enter.
Select date, Enter:
Format "DD.MM.YYYY" is defaulted for the date. Another format for the date
can be selected with the arrow buttons ← → (11). The next line on the screen 
is selected with the arrow buttons ↑ ↓ (8) and the year or month or day can be 
selected with the arrow buttons ← → (11). Press Enter.
Select time, Enter:
Default "24 hours" is preselected. Another format for the time can be selected
with the arrow buttons ← → (11). The next line on the screen is selected with 
the arrow buttons ↑ ↓ (8) and hours or minutes can be selected with the arrow 
buttons ← → (11). Press Enter.
Select defaults \ units, Enter:
Default "m / bar" is preselected. Other units can be selected with the arrow
buttons ← → (11). 
Select Defaults \ Defaults \ Leak test with compressed air, Enter:
Check defaults, edit with arrow buttons ↑ ↓ (8) or arrow buttons ← → (11) if 
necessary.
eng
19