7. Maintenance and cleaning
7. Maintenance and cleaning
7.1 Maintenance
This instrument is maintenance-free.
EN
Repairs must only be carried out by the manufacturer.
Only use original parts.
7.2 Cleaning
1. Prior to cleaning, disconnect the tension/compression force transducer from the
voltage supply and dismount it.
2. Clean the tension/compression force transducer with a cloth.
Electrical connections must not come into contact with moisture!
CAUTION!
Damage to the instrument
Improper cleaning may lead to damage to the instrument!
▶
▶
7.3 Recalibration
DKD/DAkkS certificate - official certificates:
We recommend that the tension/compression force transducer is recalibrated by the
manufacturer at regular time intervals of approx. 24 months. The basic settings will be
corrected if necessary.
For contact details see chapter 1 "General information" or the back page
of the operating instructions.
16
Do not use any aggressive cleaning agents.
Do not use any hard or pointed objects for cleaning.
WIKA operating instructions, models F2802, F2808