5. Commissioning, operation
Guide values for "hand-tight" tightening torques MA [Nm],
according to table 1 of DASt guideline 024:2018
Strength
class
EN
4.6 to 10.9
5.5 Electrical connection
To prevent interferences from coupling into the system:
Use only shielded and low-capacitance measuring cables.
Ground the shield of the measuring cable.
Connect the cable shield with the case of the tension/compression force transducer. In
the cables of the accessories, the cable shield is connected by means of the knurled
nut, thus connecting it to the case of the tension/compression force transducer.
Do not install measuring cables in parallel to 3-phase-current cables and control
cables.
Avoid stray fields of transformers, motors and contactors.
Transducers, amplifiers and processing or display units must not be grounded several
times. Connect all instruments to the same protective conductor.
The pin assignment of the connector or of the cable can be found on the product label.
When using extensions, only shielded and low-capacitance cables should be used. The
permitted maximum and minimum lengths of cable are defined in ISO 11898-2. Care
should be taken about the shielding.
5.6 Connecting an amplifier
The use of an amplifier is optionally possible.
The amplifier is not included in delivery.
The tension/compression force transducers described in these operating instructions
output a signal in mV/V based on strain gauges.
Any DC amplifiers and carrier amplifiers designed for strain gauge measuring
systems can be used.
5.7 Pin assignment cable
Electrical connection
Supply voltage +
Supply voltage -
Signal +
Signal -
Shield
14
Tightening torques MA [Nm]
M6
M10
10
12
Exc+
Red
Exc-
Black
Sig+
Green
Sig-
White
Shield
Yellow-green
M12
M16
15
35
WIKA operating instructions, models F2802, F2808
M30
M40
220
410
(Red)
(Green)
(Black)
(White)
(Yellow-green)