l
ed
k
eys Function
TEST: Pushed for 3 sec. during normal operation, it allows to activate a condensate drainage cycle.
SET: When pushed and released during normal operation, it displays the set-point value (decimal).
When pushed for 10 seconds, it allows to enter the C8 and C9 condensate drain parameters programming menu
(see relevant table).
When pushed after having set new configuration values, it stores the applied modifications.
DOWN: When pushed while setting the set point or the configuration parameters, it decreases the displayed value
of one unit per second, during the first 10 seconds, than of one unit every 0,1 sec.
When pushed for 10 seconds during normal operation, it starts an automatic test cycle of the controller.
.
UP: When pushed while setting the set point or the configuration parameters, it increases the displayed value of
one unit per second, during the first 10 seconds, than of one unit every 0,1 sec.
ON / OFF: Pushed for 3 seconds, it activates or deactivates the process. When the process is deactivated, the
display shows OFF.
NOTE: when the controller is in OFF position, some parts of the dryer are kept under tension therefore, for safety purposes, di-
sconnect the electrical power before performing any operation on the machine.
c
ondensate discHarge parameters programming
Push the SET key for 10 seconds to enter the parameters configuration menu: the display will show in sequence the set point
value, the code of the first modifiable parameter (C8) and its value).
Only if strictly necessary, use the UP and/or DOWN keys to change the displayed parameter value.
Press the SET key to store the previously changed parameter value or to browse the parameters without changing them.
15 seconds after the last performed operation, the controller will return automatically to the normal operation mode.
PARAMETER
C8
Delay between condensate discharges
C9
Time required for condensate discharge
Changes entered for timing values will be effective only after exiting the programming, while changes to other variables will be
immediately effective.
Please remember that eventual changes to the configuration parameters of the machine could negatively affect its efficiency.
Thus, changes have to be arranged in collaboration with the manufacturer.
WARNING FOR USER:
IT'S FORBIDDEN TO MODIFY THE OTHER CONFIGURATION PARAMETERS OF THE ELECTRONIC CONTROLLER WI-
THOUT THE SERVICE CENTER'S AUTHORIZATION
6. d
STATUS
ON
Blinking
ON
ON
Blinking
.
DESCRIPTION
ryer
RANGE
1 ÷ 999 (min)
1 ÷ 999 (sec)
17
DESCRIPTION
Compressor energized
Programming mode activated
Condensate drain energized
Speed of the fan = 100%
Speed of the fan < 100%
SET VALUE
1
1
EN