5.2 c
,
ontrols
indicators and saFety devices
easy air 2
control panel
The control panel is made up of a set of buttons required for the main operational and control functions of the compressor.
Control panel
1 - START button
2 - STOP button
3 - RESET button
4 - Alarm Led
Compressor state (6) - Meaning of simbols
Compressor ON
(rotors moving)
Air-end delivery temperature (5) - Possible alarms
The display shows the compressor temperature in °C or °F, it depends on the setting.
The high temperature alarm is 105°C (221 °F) and to reset the alarm the temperature has to decrease under 95 °C (203 °F).
In case of high temperature alarm, the compressor stops (regardless its status) and is not possible to start it again.
The LOW temperature alarm is -5 °C (23°F), and to reset the alarm the temperature has to be above 10°C (50°F).
In case of low temperature alarm, the compressor stops (regardless its status) and is not possibile to start it again.
If the air-end temperature drops below – 40°C (- 40 °F) it means that the temperature sensor is short circuit; in this case the com-
pressor stops immediately regardless of its status and it's not possible to start it again.
Check page 23, in order to recognize alarms signal and find a solution.
5. u
4
81
50
8.2
55
1
2
sing tHe compressor
3
Display
5 - Air-end delivery temperature
6 - Compressor state
7 - Working hours (total)
8 - Pressure
9 - Working hours (duty)
Compressor is charging
(rotors moving)
13
5
6
81
8.2
8
Idle running time
(rotors moving + countdown)
Restart time
(rotors flashing + countdown)
EN
EN
IT
7
55
50
9
OR