Blitz Monsun Fast - Easy 2 Bedienungsanleitung Seite 52

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

r
emaining Hours to maintenance
for 5 seconds to see remaining hours to main-
Push button
tenance.
If time is already expired, a negative number will be shown (e.i -3) al-
ternately to the compressor status.
u
m
- s
ser
enu
etting
Push button
and
the Setting parameters Area.
The setting menus are accesible to different levels only entering a pas-
sword.
To enter the password (111)
Push
once (display shows 100) and confirm pressing
Push
once (display shows 110) and confirm pressing
Push
once (display shows 111) and confirm pressing
MINIMUM PRESSURE setting (*)
Min = 5,5 bar / 80 psi - Max.15 bar / 218 psi
N.B display does not show comma/dot:
055 = 5,5 bar (as shown on the example)
MAXIMUM PRESSURE setting (*)
Min = 6 bar / 87 psi - Max.15,5 bar / 225 psi
N.B display does not show comma/dot:
100 = 10,0 bar (as shown on the example)
(*)To be ignored for version with pressure switch.
TO MODIFY setting
push
(value is flashing) :
Push buttons
and
By pushing
you can confirm setting and move forward.
If you don't want to change the setting press
At the end of the menus, display will show "OUT", press
During the setting procedure, if any button is not pushed for 60 seconds, the control panel will exit automatically.
5. u
sing tHe compressor
togheter for at least 5 seconds to enter
to change values , and .
to move forward, or
81
8.2
81
8.2
to confirm.
to move backward.
to exit and go back to the compressor status .
14
55
50
55
50
55
50
55
50