4.5 External Trigger

The LLB-60-D includes the option of triggering measurements with an external switch or push button
on Digital Input 1 (DI 1). Using the Digital Input DI 1 disables the Digital Output DO 1.
The command to activate the external trigger option is described in 10.4 Digital Input on page 90.

4.5.1 Configuration

After connecting the LLB-60-D, the following steps are necessary to activate the external trigger. The
example shows the configuration for triggering a single distance measurement.
No.
Action
1
Activate digital input DI1
5
Save settings
1) Commands are described in 10 Command set on page 80
TR-Electronic GmbH 2007, All Rights Reserved
Page 70 of 96
Comment
Defines the action for a trigger event
on DI1.
Example for module 0:
Configure DI1 to trigger a single
distance measurement.
The changed configuration must be
saved to make it permanent.
Example for module 0:
Save settings for module 0
TR - ELE - BA - DGB - 0015 - 02
Command
1)
s0DI1+2<trm>
1)
s0s<trm>
Printed in the Federal Republic of Germany
07/22/2009