Command set
Save configuration parameters
10.3.7
This command saves all configuration parameters, which are set by the commands above. The
parameters are written to the Flash Memory.
sNs<trm>
Command
Return successful gNs?<trm>
gN@Ezzz
Return Error
Parameters

10.3.8 Set configuration parameters to factory default (sNd)

This command restores all configuration parameters to their factory default values. The parameters
are written to the Flash Memory.
The communication parameters are also reset to factory settings.
sNd<trm>
Command
Return successful gN?<trm>
gN@Ezzz
Return Error
Parameters

10.3.9 Get Software Version (sNsv)

Retrieves the software version of the LLB-60-D.
sNsv<trm>
Command
Return successful gNsv
gN@Ezzz
Return Error
Parameters
TR-Electronic GmbH 2007, All Rights Reserved
Page 88 of 96
(sNs)
Command
N
Module ID (0..9)
zzz
Error code
Command
N
Module ID (0..9)
zzz
Error code
Command
+xxxxyyyy<trm>
N
Module ID (0..9)
xxxx
Module software version
yyyy
Interface software version
zzz
Error code