tool, since this may cause
an explosion and lead to
serious injury.
z Original accessories/
additional devices
Only use accessories and
additional devices which are
stated in the operating instruc-
tions. The use of other fasteners
or other accessories than those
recommended in the operating
instructions can represent a risk
of injury for you.
Ensure that compressed air
device repairs always use
original replacement parts and
are performed by a qualified
technician. This ensures that
the compressed air device is
safe to operate at all times.
z Before using the device
Please read and follow these operating
instructions, before you start using the
device. It is essential that you follow the
basic safety measures, in order to prevent
damage to the device and avoid injuries to
operating personnel or others present in the
working environment.
z Using the device
PLEASE NOTE: Before
using the device each time,
20
GB/IE/NI/CY/MT
please put on the protective
goggles delivered with the
product.
z Connecting the
compressed air supply
NOTE: The air stapler must only be operated
with clean, oil-atomised compressed air
and must not exceed the maximum working
pressure of 8 bar at the device. To regulate
the working pressure, the compressor must
be fitted with a pressure reducer.
Connect the device to a suitable com-
pressed air supply.
To do this, press the quick coupler of the
compressed air hose (not included in the
scope of delivery) onto the threaded
barbed fitting ¼"
The plug locks into place automatically.
Connect the other end of the compressed
air house with the (filter) pressure reducer
on the compressor.
For the fastening device to work properly,
you need to use a sufficient quantity of
filtered, dry, oiled compressed air. If the
pressure in the supply network is higher
than the maximum permitted pressure for the
fastening device, then a pressure regulating
valve with a downstream pressure relief
valve must be fitted.
NOTE: When generating compressed air
using compressors, the natural air humidity
condenses and collects as condensation in
pressure vessels and piping. This condensate
must be removed through water traps. Water
traps must be checked on a daily basis and
emptied, if necessary, otherwise corrosion
may occur in the compressed air system
and in the fastening device and this could
promote wear.
The compressor must be sufficiently dimen-
4
of the air stapler.

Werbung