Fronius Profinet Robacta CTC Bedienungsanleitung Seite 57

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Error
code
3 pulses
4 pulses
5 pulses
6 pulses
14 pulses n pulses
15 pulses n pulses
16 pulses n pulses
Supply display
LED
LEDs
Left LED off
Right LED off
Reason
for error
Cause
0 pulses
Communication bus com-
mand error
0 pulses
Communication bus data
error, break behind the
bus coupler
n pulses
Break behind bus terminal
n
n pulses
Communication bus error
during register communi-
cation with bus terminal n
0 pulses
Initialization error
1 pulse
Internal data error
4 pulses
DIP switch incorrect for
BootP
8 pulses
Internal data error
16 pulses IP socket error
nth bus terminal has an in-
correct format
Number of bus terminals
no longer matches
Length of communication
bus data no longer
matches
Meaning
No power to bus coupler
No + 24 V
power supply connected to the power contacts
DC
Remedy
-
No bus terminal inser-
ted
-
One of the bus termi-
nals is faulty, remove
half of the inserted
bus terminals and
check whether or not
there is still an error
with the remaining bus
terminals. Repeat the
process until you loca-
te the faulty bus ter-
minal.
Check whether or not the
n+1 bus terminal is inser-
ted correctly, replace if
necessary
Check whether or not the
9010 bus terminal is inser-
ted
Replace nth bus terminal
Replace bus coupler
Turn bus coupler off/on
Set 1-8 to the -Off- positi-
on
Turn bus coupler off/on
Turn bus coupler off/on
Restart bus coupler. If the
error reoccurs, replace the
bus terminal.
Restart bus coupler. If the
error reoccurs, reset the
factory settings using the
KS2000 configuration
software.
Restart bus coupler. If the
error reoccurs, reset the
factory settings using the
KS2000 configuration
software.