5.2
Switch on the system
Connect the power cable to the mains.
Move the main switch into the ON position.
Initialisation starts automatically.
The device checks the electrical components.
Operation of the control units
The auger screw control unit controls the operation of the
auger screw via the installed immersion pipe (probe for level
exceedance). The corresponding level for the immersion
pipe is set using the control unit. The skimmer unit's con-
trol unit has a timer which controls the skimmer unit. The
capacitive sensors on the respective disposal tanks provide
feedback when the disposal tanks are full. When a disposal
tank is full, the corresponding component switches off after a
remaining running time of 5 minutes.
The components can also be set to manual operation (6) as
preparation for maintenance or for troubleshooting.