Courier 5000
2%
= zero range is within +/-2%
100%
= zero range is within +/-100%
Filter
Set the amount of signal filtering.
LOwW
= faster stabilization time with less stability.
mMEd
= normal stabilization time with normal stability.
HIGH
= slower stabilization time with more stability.
AZT
Set the automatic zero tracking feature.
OFF
= disabled
.5d
= the display will maintain zero until a change of 0.5 divisions per second has been exceeded.
1d
= the display will maintain zero until a change of 1 division per second has been exceeded.
3d
= the display will maintain zero until a change of 3 divisions per second has been exceeded.

Backlight

Set the display backlight feature.
OFF
= backlight is disabled.
On
= backlight is enabled and always on.
Auto
= backlight is disabled after 20 seconds of no activity.
Auto Off
Set whether the display enters sleep mode after the selected time period.
OFF
= disabled
1
= the display enters sleep mode after 1 minute of no activity.
5
= the display enters sleep mode after 5 minutes of no activity.
10
= the display enters sleep mode after 10 minutes of no activity.
PWM.SAVE
Set whether to enable power saving mode after the scale enters standby mode. If it is enabled, it will take
about 3 seconds before the terminal returns to weighing when weight is changed on the platform or you
press the terminal's buttons.
On
= power saving is enabled.
OFF
= power saving is disabled.
Calibration Lock
There are two options for the setting of Calibration Lock, namely ON and OFF. Please refer to the table
below for details.
Menu
Calibration Menu
Setup Menu
Readout Menu
Unit Menu
Print Setup Menu
NOTE: The CAL lock cannot be reset by resetting the Readout menu. Please set the CAL lock to OFF
manually.
End Readout
Advance to the next menu or return to the top of the current menu.
Sub-menu
Zero Calibration
Span Calibration
Line Calibration
Power on unit
Zero range
Auto zero tracking
Stable Range
Reset, g, kg, lb, oz,
lb:oz
Stable only printing
Calibration Lock is OFF
Activated
Activated
Activated
Activated
Activated
Activated
Activated
Activated
Activated
Calibration Lock is ON
Hidden
Hidden
Hidden
The current unit is locked
The current value is locked at 2%.
The current value is locked at 0.5d.
The current value is locked at 1d.
The current setting is locked.
On is locked
EN-17