Page 55
© 2016 OJ Electronics A/S
All manuals and user guides at all-guides.com
This thermostat complies with EN 50559:2013 (VDE 0705-559) for electrical floor
heating . The regulation applies to electrical floor heating, with a maximum floor
weight of 4 kN/m² . To ensure that hotspots due to unintentionally covering up the
surface are avoided, the heating function can be time-limited as per EN/DIN .
Note that this function is not applicable to other heating applications such as wall
and/or ceiling heating
If it can be foreseen in advance that unintentional covering up of a floor might occur,
then it is important to assess the correct period of time for which the floor heating
must be time-limited .
The heating can be limited by using a set number of minutes per hour .
The factory setting is 0 minutes .
FRTD 903 TC:
1 . Tap the "Menu" button on the home screen .
2 . Then tap the "engineer settings" button .
3 . Scroll down and tap the "en50559" button .
4 . Use the "up arrow" or "Down arrow" button to set the number of minutes – the
thermostat should not heat per hour .
5 . Confirm the value with "√" .
6 . The thermostat will automatically return to "engineer settings" .