This option allows you to choose which sensor is used to control the heating
system .
• Floor (default): With this setting, the floor sensor controls the heating system.
• Room/Floor Limit (advanced): With this setting, the room sensor controls the
heating system subject to maximum and minimum limits for floor temperature .
The maximum temperature limit protects wooden floors from excessive heat .
The minimum temperature limit prevents the floor from becoming uncomfortably
cold when heating is not needed, e .g . in a bathroom . Note that this function will
increase energy consumption .
Floor Limit temperatures are set in the "Temperature Scale" menu .
Maximum temperature depends on floor type and temperature scale .
1 . Tap the "Menu" button on the home screen .
2 . Then tap the "engineer settings" button .
3 . Tap the "sensor application" button .
4 . Confirm that you want to set the Sensor Application .
5 . Then tap the application you want to use .
6 . Confirm your choice with "√" or discard it with "X" .
7 . The thermostat will automatically return to "engineer settings" .