26 | DCU 220 |
5.
Expand the Memory
5.1
Scope of delivery
Abb. 13: Scope of delivery, retrofit kit 1 688 400 550
1 Memory Module
2 Safety bracket
3 Fastening screw (2x)
4 Heat conducting pad
5.2
Install the RAM
!
The installation should be done in switched off con-
dition with the batteries removed.
1. Remove the screws of the cover.
2. Lift the cover at the contact point and remove from
above.
3. Mount the heat conducting pad on the metalplate.
|
1 689 975 264
2015-06-02
4. Place the Memory Module into the plug-in connector
at an angle of 30°.
5. Press the protruding end of the Memory Module till
it engages with the metal clamps.
6. Mount the safety bracket using the two screws
provided.
7. Place the cover and screw it back.
Robert Bosch GmbH