2.
Flush filter cartridges according to instruction before first usage.
OPERATION
General Instructions
When using for the first time, please open the faucet and the inlet water valve.
When water is running from tap, close the tap for 30 minutes and check for
leakages. lf there are no leaks, you can use the machine normally. In normal user
mode, keep the power connected, open and close the faucet.
When using the machine after a langer period of no usage, please open the faucet
and flush cartridges according to the instructions.
Operation
The machine is equipped with an LED display.When connecting the power
supply,the machine buzzes once and goes into rinse mode.
1. Rinse
1.
Auto rinse: Every time the power supply is connected, the machine will flush
automatically. If the machine is not used for more than 72 hours, the machine
will flush automatically.
2.
When flushing, the booster pump, the inlet water solenoid valve and the
drain water are all in working mode, flushing lasts for 15 seconds. This will be
indicated on the front panel.
3.
If you press the"Select" button once,the machine will flush for 30 seconds.
2. Purify
Turn an the water tap and start filtering,the inlet water solenoid valve and booster
pump start working,this is indicated an the front panel.
3. Fault
When continuously filtering or rinsing for 30 minutes, the fault light turns red
while buzzing for 6 seconds until the problems are solved to connect the power
again.
4. Cartridge Life
Filter life time is indicated an the front panel. Over time and usage the bars will
lower. When the last bar is arrived, a 10 second alarm goes off. After that, for 3
more times, every half an hour an alarm goes off.
5. Replace Cartridge
Press "Reset" button for 3 seconds until you hear a sound.You are in replacement
mode now.To switch between cartridges, push "Select" once. Select the cartridge
to be changed and press "Reset" button for 3 seconds until you hear a sound.
EN