Herunterladen Diese Seite drucken

Sony DG50B Serie Registrierungsanleitung Seite 11

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Cautions
• After mounting the probe, insert the connector in the display unit connector until it locks.
• Keep a strong magnetic source at least 10 cm (3.94") away from the probe (head
• Do not forcibly pull the cable, or it may break open.
• The probe is short circuited to the frame GND (ground terminal) of the display unit by shield
• The N-type probe has an unsealed spindle for use in mechanical devices and measuring
• The P-type probe is dust-proof, drip-proof, and oil-resistant making it suitable for use
• Adhesion of cutting oil, etc. which increases in viscosity after drying, may hinder
• The P-type probe is provided on the sliding portion of the spindle with an anti-drip/
Mounting Instructions
• Be sure to chuck the probe stem for mounting. If other probe portion needs to be
• When replacing the feeler, since subjecting the spindle to excessive torque may
• The probe comprises ball bearing. Therefore, chucking the probe stem too tightly
• A holder of dimensions as shown in Fig. 2 may be used to mount the probe,
• Since mounting parallelism affects the measuring accuracy, adjust the parallelism to
• Fix the cable in a suitable position to prevent its possible breakage. Never handle the
• If the spindle is to be fixed to the machine, use coupling DZ-191 which is optionally
Head built-in portion
Stem
Chuking portions
Fig. 1 Mounting positions
Be sure to turn off the power switch before connecting or disconnecting the connector.
built-in portion).
wire of the cable.
When the probe is used with an other signal processing device on a machine tool, etc., be
aware of the ground level.
rooms having a favorable work environment. Due to the low measurement force, the N-
type cannot be used with the spindle directed upward.
in environments subject to chips, cutting oil, and machine oils. However, avoid
immersing the P-type probe in cutting oil, etc., as it is not of a water-proof structure.
accurate spindle motion. Remove them with water or tepid water. Then apply
machine oil or the like to the spindle.
dust seal of nitrile rubber. Spindle movement may be impaired by exposure to cutting
oil, water, etc. that may remove oil from the spindle surface.
chucked, avoid chucking the name label portion (where the head is built in) and its
neighborhood (Fig. 1). If the probe is mounted on another device, ensure that the
probe is free from contact with mount screws.
damage the internal mechanism, always replace the feeler by hand without using
tools.
Except when using a flat feeler, it is recommended to either attach a nominal 2.5
spring washer or use a screw lock to prevent loosening of the feeler (tightening torque
reference value: 0.05-0.06 N·m).
when mounting may damage the spindle and prevent its smooth motion.
tightening the screw to about 4 N•m torque.
within 0.3 mm (0.01") in relation to 100 mm (3.94") displacement by means of mount
bracket (or sleeve).
cable by forcibly pulling or bending it. (Inside bend radius 40 mm or more)
available. Refer to the DZ-191 Instruction Manual regarding the mounting procedure.
Sleeve
φ4.5/0.18" dia., φ8/0.31" dia.
Spot facing depth 4/0.16"
30/1.18"
M4
2/0.08"
φ20
+0.013
/
+0
+0.0005"
0.79"
dia.
+0
Tightening torque: 4 N•m
Use M4 hexagon socket head cap screw.
Fig. 2 Mount holder dimensions
25/0.98"
Unit: mm/inch
1 (E)

Werbung

loading

Diese Anleitung auch für:

Dg100b serieDg50bnDg50bpDg100bnDg100bp