LUC-M10, LUC-M20, LUC-M40
SI179O-C
Max. electrical
specifications
Safety instructions:
installation
Power supply
4 mA ... 20 mA HART
2-wire
PROFIBUS PA
Power supply
U
e
4-wire
or
U
e
Signal circuit
4 mA ... 20 mA
Working pressure
LUC-M10, LUC-M20: max. 0.3 MPa
LUC-M40: max. 0.25 MPa
Process temperature
max. 80 °C
Housing
F12
(Aluminium, coated)
T12 und T12-OVP
(Aluminium, coated)
Option
Remote display
Service interface
• Install the device according to the manufacturer's instructions and any other valid standards and
regulations.
• Do not operate the device outside the specified electrical and thermal parameters.
• The relationship between the permitted ambient temperature for the electronics housing,
dependent on the range of application and the temperature classes is shown in the tables.
• Continuous duty temperature of the cable ≥ Ta +5 K.
• Do not disconnect electrical connections under voltage in an explosive atmosphere.
• Devices which are supplied by a plug (PROFIBUS PA):
Do not loosen or detach the plug as long as power is switched on.
• The maximum voltage U
m
external display (e. g. LUC-Z15) or a service adapter is connected to the device.
• The following components of the device correspond to the low risk of mechanical danger.
• They must be mounted in a protected position if installed within a hazardous location area rated
Zone 2 if mechanical danger is expected:
– Cover with inspection window
– Plug connectors of devices for supply/communication
F12 housing
• The input power circuit or the signal circuit in case of 4-wire versions of the device is isolated
from ground potential and has a dielectric strength of at least 500 V
T12 housing
• Do not open the connection compartments under voltage.
T12 OVP housing
• The input power circuit or the signal circuit in case of 4-wire versions of the device is isolated
from ground potential and has a dielectric strength of at least 410 V DC with respect to it.
= 90 V AC ... 253 V AC, 50/60 Hz, U
= 10.5 V DC ... 32 V DC, U
= 60 V AC
m
-40 ° C ≤ T
-40 ° C ≤ T
e. g. LUC-Z40-Ex*
EC-Type Examination Certificate, Statement of
Conformity, Declaration of Conformity, Attestation of
Conformity and instructions have to be observed where
applicable. For information see www.pepperl-
fuchs.com.
e. g. HART modem with programming software
PACTware
TM
of the power circuit or the signal circuit must not be exceeded if an
U = 30 VDC
specified in the respective standard
(U = 32 V DC)
= 253 V AC
Housing protection IP68
m
Observe power supply
variant
active or passive
≤ +80 ° C optionally with or without
amb
LUC-Z15 display and
operating module
≤ +80 ° C with integrated
amb
overvoltage protection,
optionally with or without
LUC-Z15 display
andoperating module