NOTE!
An inadequately dimensioned electrical installation can cause serious damage.
The mains lead and its fuse protection must be rated accordingly. The technical data
shown on the rating plate applies.
Generator-powe-
PlasmaModule 10 is generator-compatible, provided the maximum apparent power deli-
red operation
vered by the generator is at least 1.5 kVA.
NOTE!
The voltage delivered by the generator must never exceed the upper or lower
limits of the mains voltage tolerance range.
Details of the mains voltage tolerance are given in the section "Technical data".
Digital plasma
The digital PlasmaModule 10 is fitted with a digital plasma gas regulator as standard.
gas control
Plasma gas is colourless and odourless, is hazardous to health and can cause
asphyxiation.
If the following instructions are not observed, there is a risk that the control valve will not
close completely when welding has finished. Colourless and odourless plasma gas may
escape undetected.
▶
▶
▶
IMPORTANT! Before using for the first time, mount the supply pressure regulator, sup-
plied separately, on the rear of the PlasmaModule 10.
When mounting, pay attention to the sealing ring in the supply pressure regulator.
For the digital plasma gas regulator in PlasmaModule 10 to reach the maximum gas flow,
the following requirements must be met:
-
-
-
WARNING!
Use the digital PlasmaModule 10 only in conjunction with the standard supply pres-
sure regulator.
Never alter the adjusting screw on the supply pressure regulator. If the screw is
adjusted, Fronius will not accept any liability for resultant damage.
Do not exceed the maximum supply pressure of 7 bar (101.49 psi).
If the plasma gas supply has a pressure regulator, open it fully after connecting the
gas hose.
The pressure regulator with measuring tube (item number: 43,0011,0008) is not sui-
table, as it does not permit an adequate supply pressure to be reached.
If the plasma gas and shielding gas are supplied from gas cylinders: use separate
gas cylinders for the plasma gas and shielding gas.
73