BOS R254K-UUI-LH11-S4
Photoelectric Sensors
7
System Functions (continued)
7.4
Variant Configuration
After a variant changeover, an inconsistent
configuration may occur because there is no
automatic changeover of parameters.
It is therefore recommended that the setup be
done in the following order:
1. Variant setting
2. Perform factory reset or set valid parameters.
7.4.1
Description
Allows switching between different process data profiles,
as well as switching between the ADSS Smart Sensor
Profile and Legacy Smart Sensor Profile.
7.4.2
ISDU
Name
Index
Device Variant
0x0055 (85)
Tab. 7-10: Variant Configuration – ISDU
Device Variant
This parameter indicates which variant is currently set. The
device variant can be changed either with this parameter
or by using the IO-Link compatibility mode. If this
parameter is written, the device variant is not changed
immediately but instead after the device is restarted. If the
device variant is changed via the IO-Link compatibility
mode, the change in this parameter is visible immediately.
This parameter is not changed by a reset.
The following device variants are available:
Value
Meaning
0x0001 (1)
ADSS
0x0002 (2)
LSSC
0x0003 (3)
CM
0x0004 (4)
CNT
0x0005 (5)
CCM
Tab. 7-11: Overview of device variants
Also see section Process Data Profiles on page 10.
94
english
Subindex
Access
Length
0
R/W
2 bytes
Description
ADSS-Smart-Sensor-Profile-compliant process data profile
Legacy-Smart-Sensor-Profile-compliant process data profile
LSSC + further Condition-Monitoring information in the process data
LSSC + further Counter information in the process data
Comprehensive Condition Monitoring
Data Type
Data Storage
UINT16(ENUM)
Yes
Default
1