Herunterladen Inhalt Inhalt Diese Seite drucken

Nussbaum POWER LIFT HDL 6500 SST DG Originalbetriebsanleitung Seite 126

Vorschau ausblenden Andere Handbücher für POWER LIFT HDL 6500 SST DG:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Made
in
Germany
8.3.4 Hilti injection anchor (2.65 HDL SST, 2.70 HDL SST, 2.80 HDL SST)
Quality of concrete Normal armouring
subject to alterations!
Adhesive and anchor rod:
Art. Hilti:
Seismic / filling set or suitable filling method
Effective anchoring depth:
Material:
Registration number:
Issued / valid:
Anchor plate:
Ground:
Installation:
Reinforcement:
Observe necessarily the installation description of the dowel manufacturer. Use longer dowels with version with floor
pavement and tiles.
It is possible to use equivalent injections dowels (with license) of other manufacturer but observe their regulations.
126
HIT-HY 200-A + HIT-V (5.8) M16
387066 HIT-V-5.8 M16x300 / 2022696
h
= 190.0 mm
ef
5.8
ETA 11/0493
2/3/2017 | -
lx x ly x t = 850.0 mm x 525.0 mm x 30.0 mm
Cracked concrete, C20/25, fc,cube = 25,00 N/mm2; h = 226,0 mm, Temp.:
24 °C (max. 40 °C)
Drilled hole: hammer-drilled, dry
No reinforcement or rod spacing ≥ 150 mm (each diameter) or ≥ 100 mm
(diameter ≤ 10mm)
No edge length reinforcement
Reinforcement is provided to prevent cracks according to EOTA TR 029,
5.2.2.6.