Herunterladen Inhalt Inhalt Diese Seite drucken

Nussbaum POWER LIFT HDL 6500 SST DG Originalbetriebsanleitung Seite 115

Vorschau ausblenden Andere Handbücher für POWER LIFT HDL 6500 SST DG:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
1
LED OUT 1
2
LED OUT 2
3
LED OUT 3
4
LED OUT 4
5
2 LED RED ENCODER AXIS 1
6
2 LED RED ENCODER AXIS 2
7
2 LED RED ENCODER AXIS 3
8
2 LED RED ENCODER AXIS 4
9
X603 X604 4 JUMPER FOR
INTERFACES SWITCHOVER
10
X601 RS232- CONNECTOR
11
GREEN LED: USB RECEIVING
12
RED LED: USB TRANSMITTING
13
X600 USB TYPE B CONNECTOR
14
X602 2XCAN BUS CONNECTOR
15
JP600 CAN 1 TERMINATION
16
S1100 CPU RESET BUTTON
17
JP601 CAN 2 TERMINATION
18
GREEN LED: CAN STATUS
19
RED LED: CAN STATUS
20
JP1100 JUMPER FOR PROGRAMMING
21
S1101 DIP SWITCHES 1-8
22
X1101 CONNECTOR FOIL KEYBOARD
Designator: JP1100
Purpose
Open
Closed
Standard
Designator: JP600
Purpose
Open
Closed
Standard
OPI_POWER LIFT HDL 6500 SST DG-7000 SST DG-8000 SST DG_V4.0_DE-EN-FR-ES-IT
Programming mode See
description Programming
the μControllers
Normal operation
Programming
Open
Can BUS 1
See below under CAN-Bus
No termination
120 Ω termination
Closed
23
X1100 DISPLAY CONNECTOR
24
GREEN LED: CPU STATUS (FLASHES)
25
P1101 POTENTIOMETER CONTRAST DISPLAY
26
X501 ZERO JUMPER PIC
27
LED GREEN 5 V
28
LED GREEN 3.3 V
29
RED LED: IN 1
30
RED LED: IN 2
31
RED LED: IN 3
32
RED LED: IN 4
33
RED LED: IN 5
34
RED LED: IN 6
35
RED LED: IN 7
36
RED LED: IN 8
37
GREEN LED: RELAY K500
38
GREEN LED: RELAY K700
39
X901 64-PIN CONNECTOR STRIP
40
K700 RELAY CPU MONITORING
41
K500 RELAY PIC MONITORING
42
LED PWM 1
43
LED PWM 2
44
LED PWM 3
45
LED PWM 4
Designator: X501
Purpose
Closed
Standard
Potentiometer P1101 contrast for LCD Display
The contrast for the LCD display can be adjusted with the
P1101 potentiometer.
After changing a display this must be reset under certain
circumstances, especially if the dis-play does not appear
or there are black squares.
Reset S1100 button
After activation of the S1100 button the microprocessor
performs a reset, i.e. the program restarts. This is similar
to switching on the 24V supply voltage again.
DIP switch S1101
The sliding switches 1 to 8 of the S1101 switch block can
be switched off and on. The position on the side with the
designation „ON" means that the switch is turned on.
The meaning of the switch is determined in the program,
i.e. it has no application-specific functions.
Zero PIC
See description PIC
See figure 4a + 4b
Zeroing after switching on if
opened within 2s
Open
115

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis