BIR 01-_ _ _ _-K1_ _ L_... / BIR 02-_ _ _ _-P1 _ _ L _...
Inductive Rapid Positioning System
4
Primary Device Functions (continued)
4.3

Operation modes

The sensors support three operation modes:
High speed
High precision
Balanced
High speed
In this mode the position is updated more frequently;
however, the device may cause a higher noise level.
High precision
In this mode the position is updated less frequently;
however, the device works more accurately.
Balanced
This mode ensures a balance between high speed and
high precision.
4.3.1
ISDU
Name
Index
Operation mode
0x0129
(297)
Tab. 4-4:
Operation mode – ISDU
4.3.2
Operation mode
Value
Meaning
0x01 (1)
High speed
0x02 (2)
Balanced
0x03 (3)
High precision
Tab. 4-5:
Operation modes – Values
The reset command must be performed so that
the changes to the values become effective.
4.3.3
Variant Dependence
The functionality is available in all variants.
www.balluff.com
Subindex
Access
Access to
prod. mode
0
R/W
R/W
Length
Data Type
Data Storage
1
UINT8
english
Default
yes
23