BIR 01-_ _ _ _-K1_ _ L_... / BIR 02-_ _ _ _-P1 _ _ L _...
Inductive Rapid Positioning System
5
Secondary Device Functions (continued)
5.6

Voltage and Current Monitoring

5.6.1
Description
The voltage and current module sends messages about
over-current, short-circuit, wire breakage, over-voltage and
under-voltage. Over-voltage and under-voltage detection
starts a timer. If the timer has expired and the voltage level
has not returned to the normal operating voltage threshold,
the module sends out the messages.
The messages include device status, IO-Link events,
process data and LED signaling.
5.6.2
Mathematics/Algorithm
SIO mode: Undervoltage
In SIO mode two thresholds apply for the undervoltage:
11 V and 9 V.
11 V applies for the following device variants:
BIR 01-_ _ _ _-K12LL3-000S04
BIR 02-_ _ _ _-P12LL3-000S04
9 V applies for the following device variants:
BIR 01-_ _ _ _-K15AL_-000S92
BIR 01-_ _ _ _-K15SL_-000S15
BIR 02-_ _ _ _-P15AL_-000S92
SIO mode: Overvoltage
In SIO mode the threshold for overvoltage is 33 V. This
threshold applies to all device variants.
IO-Link mode
If the device is in IO-Link operation, the undervoltage state
occurs at 17 V and at 33 V for overvoltage.
5.6.3
Process Data
Object ID
Name
0x0017 (23)
Undervoltage
0x0018 (24)
Overvoltage
Tab. 5-26: Voltage and current monitoring – Process data
Also see chapter Process Data Profiles on page 9.
5.6.4
ISDU
Name
Voltage Monitoring Detection
Time Duration
Tab. 5-27: Voltage and current monitoring – ISDU
44
english
Description
TRUE = the voltage level is below the threshold value.
TRUE = the voltage level is above the threshold value.
Index
Subindex
Access
0x2200
0
R/W
(8704)
Length
Data Type
Data Storage
2 bytes
UINT16
Direction
Input
Input
Default
yes
10