9 Manufacturer's information

9 Manufacturer's information

9.1 Delivery

● Check that all parts are present and check for any damage
immediately upon receipt.
The product's performance is tested at the factory. The scope
of delivery is apparent from the dispatch documents and the
design from the order number.
Control
Function
function
1
Normally closed (NC)
2
Normally open (NO)
3
Double acting (DA)

9.2 Packaging

The product is packaged in a cardboard box which can be re-
cycled as paper.

9.3 Transport

1. Only transport the product by suitable means. Do not drop.
Handle carefully.
2. After the installation dispose of transport packaging ma-
terial according to relevant local or national disposal regu-
lations / environmental protection laws.

9.4 Storage

1. Store the product free from dust and moisture in its ori-
ginal packaging.
2. Avoid UV rays and direct sunlight.
3. Do not exceed the maximum storage temperature (see
chapter "Technical data").
4. Do not store solvents, chemicals, acids, fuels or similar
fluids in the same room as GEMÜ products and their spare
parts.
GEMÜ 695
Condition as supplied
to customer
closed
open
undefined
64 / 80

10 Installation in piping

10.1 Preparing for installation

The equipment is subject to pressure!
▶ Risk of severe injury or death
Depressurize the plant.
Completely drain the plant.
Corrosive chemicals!
▶ Risk of caustic burns
Wear appropriate protective gear.
Completely drain the plant.
Actuator under spring pressure!
▶ Risk of severe injury or death!
Only open the actuator under a press.
Hot plant components!
▶ Risk of burns
Only work on plant that has cooled
down.
Use as step.
▶ Damage to the product
▶ Risk of slipping-off
Choose the installation location so that the product can-
not be used as a foothold.
Do not use the product as a step or a foothold.
Leakage
▶ Emission of dangerous materials.
Provide precautionary measures against exceeding the
maximum permitted pressures caused by pressure
surges (water hammer).
Suitability of the product!
▶ The product must be appropriate for the piping system
operating conditions (medium, medium concentration,
temperature and pressure) and the prevailing ambient
conditions.
WARNING