Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BOS R254K-UUI-LE10-S4 Konfigurationsanleitung Seite 179

Optoelektronische sensoren
Vorschau ausblenden Andere Handbücher für BOS R254K-UUI-LE10-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BOS R254K-UUI-LE10-S4
Photoelectric Sensors
6
Secondary Device Functions (continued)
6.5.6
Events
Event Code
Event Type
0x8D07 (36103)
Warning
0x8D0E (36110)
Notification
Tab. 6-31: Basic statistics – Events
6.5.7
Variant Dependence
The functionality is available in all variants.
www.balluff.com
Description
The calculation of the basic statistics was stopped
automatically to avoid a buffer overflow.
The time has elapsed. This event reports the timeout of
the minimum value/maximum value/average calculation.
It does not report a timeout for the calculation of the
moving average because the timer repeats and it does
not indicate the end of the calculation.
Device Status
0 – Device is
operating properly.
0 – Device is
operating properly.
english
69

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis