BOS R254K-UUI-LE10-S4
Photoelectric Sensors
3
Overview of IO-Link Data and Functions (continued)
Name
Index
Device Status
0x0024
(36)
Detailed Device Status
0x0025
(37)
Diagnosis Level
0x0070
Configuration
(112)
Event Code
0x0071
Suppression
(113)
Event Code
Suppression
Event Code
0x0072
Suppression Teach-in
(114)
Event Code
0x0073
Suppression Delete
(115)
System Commands
0x0002
Device Variant
0x0055
(85)
Pin 4 Function
0x0090
(144)
Behavior IO-Link
Mode
Pin 4 Digital
0x0091
Configuration
(145)
Signal Source
Logic
Type
Pin 2 Function
0x0093
(147)
Behavior IO-Link
Mode
Pin 2 Digital
0x0094
Configuration
(148)
Signal Source
Logic
Type
LED Standard
0x00FD
Selection
(253)
www.balluff.com
Sub-
Access
index
Device Status and Detailed Device Status
0
R
0
R
Diagnosis Suppression
0
R/W
0
R/W
1...5
R/W
0
W
0
W
Reset Commands
0
W
(2)
Variant Configuration
0
R/W
Pin Assignment
0
R/W
1
R/W
2
R/W
0
R/W
1
R/W
2
R/W
3
R/W
0
R/W
1
R/W
2
R/W
0
R/W
1
R/W
2
R/W
3
R/W
LED Meaning and Configuration
0
R/W
Length
Data Type
1 byte
UINT8
30 bytes
UINT8[]
1 byte
UINT8(ENUM)
10 bytes
2 bytes
UINT16
2 bytes
UINT16
2 bytes
UINT16
1 byte
UINT8
2 bytes
UINT16(ENUM)
2 bytes
1 byte
UINT8(ENUM)
1 byte
UINT8(ENUM)
4 bytes
2 bytes
UINT16(ENUM)
1 byte
UINT8(ENUM)
1 byte
UINT8(ENUM)
2 bytes
1 byte
UINT8(ENUM)
1 byte
UINT8(ENUM)
4 bytes
2 bytes
UINT16(ENUM)
1 byte
UINT8(ENUM)
1 byte
UINT8(ENUM)
1 byte
UINT8(ENUM)
Data
Default
Storage
n/a
–
n/a
0x00 0x00 ... 0x00
Yes
0
Yes
No
0
n/a
–
n/a
–
n/a
–
No
0x0001 (1)
Yes
No
0x00 (0) IO-Link
No
0x01 (1) =
Digital Output
Yes
No
0x0038 (56) = ADSS1
No
0x00 (0) = Normal
No
0x02 (2) = Push-Pull
Yes
No
0x01 (1) =
Normal Operation
No
0x01 (1) =
Digital Output
Yes
No
0x003A (58) = LSSC1
No
0x00 (0) = Normal
No
0x02 (2) = Push-Pull
Yes
0
english