9. Specifications
Model
Rated force F
Relative linearity error d
EN
Relative reversibility error
Relative creep, 30 min. at F
Temperature effect on
characteristic value TK
zero signal TK
Limit force F
L
Breaking force F
Permissible vibration loading F
Rated displacement (typical) s
Material of the measuring body
Rated temperature range B
Service temperature range B
Storage temperature range B
Electrical connection
Output signal
(Rated characteristic value) C
Current/power consumption
Supply voltage UB
Load
Response time
Ingress protection (per EN/IEC 60529) IP67
Vibration resistance
Electrical protection
Immunity
Options
1) Relative linearity error is specified in acc. with Directive VDI/VDE/DKD 2638 Chap. 3.2.6 / 2) Protocol in accordance with
CiA 301, instrument profile 404, communication service LSS (CiA 305) / 3) Other response times possible upon request
®
CANopen
and CiA
30
kN [lbf]
nom
1)
lin
nom
c
0
B
rb
nom
T, nom
T, G
T, S
nom
®
are registered community trademarks of CAN in Automation e. V.
WIKA operating instructions, models F2301, F23C1, F23S1, F2303, F2304
F2303
10, 18, 20, 34, 45 [2,248; 4,047; 4,496; 7,644; 10,116]
±0.5 % F
nom
< 0.1 % F
nom
0.1 % F
nom
0.4 % F
/ 10 K
nom
0.4 % F
/ 10 K
nom
150 % F
nom
300 % F
nom
±50 % F
(in accordance with DIN 50100)
nom
< 0.1 mm [< 0.004 in]
Corrosion-resistant stainless steel 1.4542, ultrasound-
tested 3.1 material (optionally 3.2)
-20 ... +80 °C [-4 ... +176 °F]
-30 ... +80 °C [-22 ... +176 °F]
-40 ... +85 °C [-40 ... +185 °F]
Circular connector M12 x 1, 4-pin
4 ... 20 mA, 2-wire
■
4 ... 20 mA, 3-wire
■
DC 0 ... 10 V, 3-wire (optional redundant signal)
■
®
CANopen
■
Protocol in accordance with CiA 301, instrument
profile 404, communication services LSS (CiA 305),
configuration of the instrument address and baud
rate Sync/Async, Node/Lifeguarding, heartbeat; zero
and span ±10 % adjustable via entries in the object
2)
directory
Current output 4 ... 20 mA, signal current: 2-wire
DC 10 ... 30 V for current output
≤ (UB – 10 V)/0.024 A for current output
< 1 ms (within 10 % to 90 % Fnom)
20 g, 100 h, 50 ... 150 Hz (per DIN EN 60068-2-6)
Reverse polarity protection, overvoltage and short-
circuit resistance
Per DIN EN 61326-1/DIN EN 61326-2-3
(optionally EMC-protected versions)
Certificates, strength verifications, 3D/CAD files (STEP,
IGES) on request
3)