5. Commissioning, operation
5.5
Mounting of model F2303
Counter nut
Thread
Force transducer
1
Place the swivel head in the clamping
instrument, insert the retaining bolt into
the hole of the clamping instrument and
thus fix the measuring unit. The retaining
bolt must not restrict the free location of
the force transducer.
Guide values for "hand-tight" tightening torques M [Nm],
according to table 1 of DASt guideline 024:2018
Strength
Tightening torques M [Nm]
class
M12
15
4,6 to 10,9
WIKA operating instructions, models F2301, F23C1, F23S1, F2303, F2304
Clamping system
Retaining bolt
Screw force transducer onto thread of
the measuring object. Do not screw in all
the way! If the measuring object must be
fixed, secure it with a nut. Observe the
recommended torque (see table below).
Load the force transducer.
M20
M24
60
110
2
M39
M45
390
495
M56
M64
640
760
17
EN