16.3.5 Dry contact (240)
240 Relay control
241 Ctl. Relay 1
242 Ctl. Relay 2
241 Ctl. Relay 1
Mode:
Deactivated
242 Ctl. Relay 2
Mode:
Deactivated
16.3.6 External stop (250)
250 External stop
Mode:
On
16.3.7 Save and load (300)
The USB interface must be activated before it can be
used!
Deactivate the USB interface again after use!
A detailed description of the functions is provided in the
"Saving and loading data and settings" chapter of the
manual.
300 USB features
Status:
Deactivated
Firmware update
Save settings
Saving of swap data
Creating reports
Loading settings
Service
Operation and installation manual for SOLIVIA 11 EU G4 TR
Explanation
Control of relay 1
Control of relay 2
Explanation
Deactivated / Activated
Supply / Temp. too high / User
setting / E-Power off / Failure /
Warning / Feed-in ongoing
Explanation
Deactivated / Activated
Supply / Temp. too high / User
setting / E-Power off / Failure /
Warning / Feed-in ongoing
Explanation
On | Off
Explanation
Activate/Deactivate the USB
interface
Firmware update
The settings should always be
saved to be on the safe side.
Saving data for replacing the
device. The data can only be
loaded during initial commis-
sioning.
Creating various reports
The settings can also be
loaded during initial commis-
sioning.
Start the service monitoring
16.3.8 Production information (400)
400 Production info
410 Current data
420 Day statistics
430 Week statistics
440 Month statistics
450 Year statistics
460 Total statistics
470 Feed-in settings
410 Current data
411 Current overview
412 Current data AC
417 Current data PV
41A Date and time
41B Current isolation
411 Current overview
Now:
200W
Day:
2000Wh
Normal operation
412 Current data AC
L1 voltage:
---V
L1 Freq.:
--.--Hz
L1 Current:
-.--A
L1 P:
---W
L1 Q:
---Var
L1 DC inj.:
---mA
416 Current data PV
PV1 Voltage:
---V
PV1 Current:
-.--A
41A Date and time
Date:
07.01.2012
Time:
15:05:19
41B Current isolation
R iso+:
----kΩ
R iso-:
----kΩ
420 Day statistics
421 Day statistics AC
422 Day statistics PV
423 Day statistics ISO
430 Week statistics
440 Month statistics
450 Year statistics
460 Total statistics
470 7-day statistics
480 Event journal
Appendix
Explanation
Current power and energy
values. Messages on the cur-
rent operating status.
Statistics for the current day
Statistics for the current calen-
dar week
Statistics for the current calen-
dar month
Statistics for the current calen-
dar year
Statistics for the entire operat-
ing period
Settings for currency and rev-
enue per kWh
Explanation
Current status
AC = AC side
PV = module side
Date and time
Isolation resistance value
Explanation
Current active power
Energy production current day
Current status messages
Explanation
Voltage
Frequency
Phase current
Active power
Apparent power
Feed-in current
Explanation
Voltage on the PV side
Current on the PV side
Explanation
Current date
Current time
Explanation
Isolation resistance at DC+
Isolation resistance at DC--
Explanation
AC = AC side
PV = Module side
ISO = Isolation
63
EN