It is advisable to remove the wire spool before lifting or transporting the welding power source.
SETTING UP THE EQUIPMENT
• Place the welding power source on a floor with a maximum inclination of 10°.
• Provide sufficient space to ventilate the welding power source and access the controls.
• Do not use in an area with conductive metal dust.
• The welding power source should be protected from heavy rain and not exposed to direct sunlight.
• The machine is IP23S rated, meaning:
- its dangerous parts are protected from being entered by objects greater than 12.5 mm and,
- it is protected against rain falling at an angle of up to 60° from vertical, providing that any moving parts (fan) are stationary.
This product can therefore be stored outdoors in accordance with the IP23 protection rating.
Stray welding currents can destroy earthing conductors, damage electrical equipment and devices and cause component parts
to overheat leading to fires.
- All welding connections must be firmly secured and regularly checked!
- Make sure that the item's attachment is firm and secure, without any electrical problems!
- Join together or suspend any electrically conductive parts of the welding source such as the frame, trolley and lifting systems so that they are
insulated!
- Do not place other equipment such as drills or grinding devices etc. on the welding source, trolley, or lifting systems unless they are insulated!
- Always place welding torches or electrode holders on an insulated surface when not in use!
The power cables, extensions and welding cables must be fully uncoiled to prevent overheating.
The manufacturer assumes no responsibility for damage to persons or objects caused by improper and dangerous use of this
equipment.

MAINTENANCE / RECOMMENDATIONS

Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
Switch off the power supply by pulling the plug and wait two minutes before working on the equipment.. Inside the macine, the
voltages and currents are high and dangerous.
• Regularly remove the cover and blow out any dust. Take advantage of the opportunity to have the electrical connections checked with an insulated
tool by a qualified professional.
Regularly check the condition of the power cable. If the power cable is damaged, it must be replaced by the manufacturer, the after sales service
team or an equally qualified person to avoid any danger.
• Leave the welding power source vents free for air intake and outflow.
• Do not use this welding power source for thawing pipes, recharging batteries/storage batteries or starter motors.
400T-W :
The coolant should be changed every 12 months to prevent residue from clogging the torch's cooling system. Any leaks or pro-
duct residues found after use, must be treated in an appropriate treatment plant. If possible, the product should be recycled. It is
forbidden to drain the used material into waterways, pits or drainage systems. Diluted fluid should not be emptied into the sewage
system, except where allowed under local regulations.
INSTALLATION - USING THE PRODUCT
Only experienced personnel, authorised by the manufacturer, may carry out the machine's set-up. During set-up, ensure that the power source is
unplugged from the mains. Series or parallel power source connections are not allowed. It is recommended to use the welding cables supplied with
the unit in order to obtain the best possible product performance.
DESCRIPTION
This machine is a three-phase power source for semi-automatic, software-supported welding (MIG or MAG), coated electrode welding (MMA) and
refractory electrode welding (TIG). It accepts 200 and 300 mm diameter wire spools.