9
Technical data
9.1 Operating limit values
Total head
Medium to be pumped
Speed
Flow rate
Switching frequency Y-2951W-MM
Max. total head
Y-2951W-MM
Medium to be pumped
Temperature
Casing: metal
Density
Viscosity
Speed
Tab. 12 Operating limit values Y-2951W-MM
9.1.1
Media to be pumped
Liquids
free of abrasive contaminations
without solid content
matched to the casing materials
9.1.2
Flow rates
 The characteristic curves are included in the Appendix
The pump must not be operated beyond the size-dependent
power ranges (min./ max. flow rate).
9.1.3
Switching frequency
No. of switching cycles per hour
Tab. 13 Switching frequency

9.2 General technical data

The following data refer to standard values. For deviating data,
please consult the manufacturer.
9.2.1
Dry running protection
The aggregate is not protected against dry running. Dry running
protection has to be provided at the installation site.
9.2.2
Service life
The service life of the aggregate is approx. 20,000 h.
Any data referring to the service life of the aggregate are
subject to conditions of use in accordance with the manu-
facturer's specifications.
9.2.3
System pressure
The max. permissible static system pressure of the aggregate is
2.5 bar.
9.2.4
Weight
2.0 kg (weight aggregate)
22
[m]
45
Water, mixtures
[°C]
max.
80
[kg/m³]
max.
1000
[mm²/s]
max.
100
2000 - 5000
40
1096.0909 | Y-2951W-MM
9.2.5
Sound level
Type
1m measured surface sound
Y-2951W-MM
* Measured surface sound pressure level in acc. with DIN EN
ISO 3744, at 1 m distance with average throttling
(cavitation-free operation) and connected pipes,
tolerance ± 3 dB (A)
Tab. 14 Sound pressure level
9.2.6
Drive
Motor power
max. 180 W
Nominal voltage
24 V
Operating range
18 – 28 V
Power consumption
max. 7.5 A
Electrical protection
10 A
Degree of protection
IP 54
Direction of rotation
right, arrow on volute casing
Blocking protection
yes, unlimited start-up tests
Overload protection
integrated
Max. surface tempera-
approx. 95 °C
ture
Tab. 15 Drive data
9.2.7
Operating connections
 Dimension drawing / Appendix
9.2.8
Sealing
The aggregate is hermetically sealed by the separating can. The
separating can and the volute casing are sealed by means of an
O-ring. Another O-ring is used to seal the gap between the
motor and the separating can.
9.2.9
Ambient conditions
The aggregate should be installed at a dry place either
indoors or outdoors under a roof. The ambient air must be
free of vapours containing acid or solvents.
Do not use in Ex zones.
Operation under other ambient conditions has to be agreed
with the manufacturer.
Relative humidity [%]
Temperature
[°C]
long-term
-30 to +40
≤ 35
Tab. 16 Ambient conditions
pressure level
L [dB (A)] *
46
Set-up alti-
tude above
short-term
sea level [m]
≤ 80
≤ 1000
08/2010