5.9.
ELECTRICAL WIRINGS
BEFORE PERFORMING ANY OPERATION,
ENSURE THAT THE MAIN POWER SUPPLY IS
DISCONNECTED
The appliance is equipped with a 1.5 meter
H05VV-F 3x1.5 power supply cable.
•
The electrical wiring to the control panels
must be carried out by qualified person-
nel according to the diagram provided.
•
perform a control of the electrical system
verifying its compliance with the regula-
tions in force.
•
Check that the system is adequate for
the maximum input power absorbed by
the water heater.
•
Make sure that the voltage and frequency
shown on the rating plate correspond to
those of the mains power supply.
Make the connect with cables having a sec-
tion appropriate for the power used and in
accordance with local regulations. Their di-
mension must in any case be such to achieve
a voltage drop of less than 3% of the nomi-
nal during the starting phase.
•
The use of adapters, multiple sockets and/
or extensions is not permitted for the gen-
eral power supply of the heat pump.
•
It is the responsibility of the installer to
provide for the installation of a power
switch-disconnecter as close as possible
to the unit and all necessary for the pro-
tection of the electrical parts.
•
Connect the unit to an effective earth
•
The use of the pipes of the water system,
heating or gas is prohibited for the earth
connection of the unit.
•
The manufacturer of the appliance can
not be held responsible for any damage
caused by the lack of earthing of the sys-
tem or for power supply faults.
•
A 16A bipolar switch in compliance with
current CEI-EN regulations protected by
a 30m
differential switch must be used
A
for the exclusion of the appliance from
the mains power supply(see figure).
1
Meter
2
30mA differential switch
3
16A bipolar switch