Partial opening
Stop
3.1.2 Obstacle detection mode
• When an obstacle is detected during opening, the gate will stop and
then withdraw
• When an obstacle is detected during closing, the gate will stop and re-
open.
When an obstacle has been detected, allow the gate to open fully.
3.2

Specific modes

3.2.1 Operation with a 3-button remote control
3.2.2 Photoelectric cells operation
Cells obscured when opening = the status of the cells is disregarded, and the
gate continues to move.
Cells obscured when closing = stop + complete reopening.
If the cells are blocked for 3 minutes or more, the system switches to "wired
dead man" mode. In this mode, a command via the wired input causes
movement at low speed.
The movement lasts for as long as the command is issued, and stops when it
is discontinued. The system switches back to normal mode as soon as the
cells are no longer blocked.
CAUTION
"Wired dead man" mode requires the use of a safety contact (e.g. keyed re-
versing switch).
3.2.3 Operation with orange flashing light
The orange light is activated during any gate movement.
10
A 2-s advance warning before movement begins can be programmed during
installation.
3.2.4 Area lighting operation
Depending on the programming performed during installation, the lighting
will come on as soon as the motor is started up, and go off after the pro-
grammed time delay.
If a remote control is programmed to control the lighting, it operates as fol-
lows:
With a 2 or 4 button remote control
With a 3-button remote control
3.2.5 Operation with automatic closing
Automatic closing will take place after a time delay programmed during in-
stallation.
A new command sent during this time delay will cancel automatic closing,
and the motorised product will remain open.
The following command will close it.
3.2.6 Operation using the backup battery
If a backup battery is installed, the drive can run even during a power outage.
It will operate under the following conditions:
With a 9.6V battery:
• Low speed
• The peripherals (photoelectric cells, orange light, wired code keypad,
etc.) will not operate.
With a 24V battery:
Operates as normal: nominal speed, accessories functional.
Battery capacities:
• Life: 24 h; 3 operating cycles for an io motor, and 5 operating cycles
for an RTS motor, depending on the weight of the gate.
• Recharging time: 48 h
• Service life before replacement: Approximately 3 years.
3.3

Adding a 4-button remote control

This operation is used to copy the function of a button on a memorised re-
mote control to a button on a new remote control.
Copyright
2s
©
2022 SOMFY ACTIVITES SA. All rights reserved.