Error 1: flow sensor defective
Error 2: the flow temperature is higher than the maximum flow temperature + 5 K for
over 5 min
Error 3: the flow temperature is higher than the holding temperature + rise value for over
30 min
Error 4: the flow temperature is higher than the set flow temperature + rise value for over
2 h
Error 5: the flow temperature is lower than the set flow temperature - rise value for over
a rise time period
The left button (⟲) can be used any time for changing to the status or main menu
of the controller in order to carry out adjustments.
When the screed drying function has been successfully completed, the heating cir-
cuit changes to its previously selected operating mode.
Screed drying is automatically deactivated. The chimney sweeper function is auto-
matically activated.
Note:
Make sure the heating circuit is supplied with heat from a heat source
(backup heating).
Note:
If a Micro SD card has been inserted into the slot, a screed protocol will
be generated.
Heating / Screed drying
Adjustment
Description
channel
Funct.
Activation / Deactivation
TStart
Start temperature
TMax
Holding temperature
Rise
Temperature increase per rise time
Rise time
Duration for emperature increase
tBacking
TMax holding time
34
9
In the Basic settings menu, all basic parameters for the controller can be adjust-
ed. Normally, these settings have been made during commissioning. They can be
subsequently changed in this menu.

Basic settings

Adjustment range /
Factory
selection
setting
Activated, Deactivated Deactivated
10 ... 30 °C
20 °C
20 ... 60 °C
30 °C
1 ... 10 K
2 K
1 ... 24 h
24 h
1 ... 20 d
5 d
Basic settings
Adjustment
Description
channel
Language
Selection of the menu language Deutsch, English, Français, Español,
Auto DST
Daylight savings time selection Yes, No
Date
Adjustment of the current date 01.01.2001 ... 31.12.2099
Time
Adjustment of the current time 00:00 ... 23:59
Temp. unit
Temperature unit
Scheme
Scheme selection
Reset
back to factory setting
Factory
Adjustment range / selection
setting
Deutsch
Italiano, Nederlands, Türkçe,
České, Polski, Portugues, Hrvatski,
Română, Български, Русский, Suomi,
Svenska, Magyar
Yes
01.01.2014
-
°C, °F
°C
1 ... 4, 202 ... 804
1
Yes, No
No