Troubleshooting:
Fault
Abnormal noise from
the rubber blades
during operation
The momentum arm
of the gear motor
vibrates violently
Direction of rotation
reversed
Material has difficul-
ties from falling out
of the separator, or
the suctional effect
at productional loca-
tion reduced
Separator will not
operate
Motor protection
switched off due to
overheating
Cause
Incorrect adjustment of the plas-
tic edges, which leads to rubber
plates and sealing segments not
being lubricated.
Foreign object in the separator
Incorrect adjustment of the plas-
tic edges, which leads to rubber
plates and sealing segments
not being lubricated. The rubber
plates will therefore briefly bond to
the sieve, causing the rotor to run
unevenly
Connection of phases reversed
Worn out rubber blades
Material is piled up in lumps
Material is not removed immedi-
ately on outlet side
Material fall velocity to low
Material is supplied in to large
amount
Safety switch disconnected
Overload protection disabled due
to overheating
Missing signal from device control
unit
Fuses defect
Foreign object in the separator
Rotor is frozen and stuck
Motor or gear defect
Rotor deformed
Overload protection incorrect
adjusted
Major decrease in voltage supply
Fuses defect
Remedy
Adjust or replace the plastic edges according to "Ser-
vice and maintenance"
Remove foreign object
Adjust or replace the plastic edges according to "Ser-
vice and maintenance"
Connect L1, L2 and L3 correct, and ensure the rub-
ber blades are positioned correctly prior to start
Renew rubber blades and sealing segments (and
possibly also plastic edges)
Composition of material should be modified at pro-
ductional location
Ensure sufficient emptying
Composition of material should be modified at pro-
ductional location
Material amount should be reduced
Turn on safety switch
Refer to "Overload protection disabled due to over-
heating"
Check control unit
Locate cause of fuse malfunction and replace fuses
Remove foreign object
Defreeze with hot water or air
Replace gear motor
Replace rotor
Adjust correctly
Replace supply cables to larger cross section
Locate cause of fuse malfunction and replace fuses