Electrical Connection
4.2
Supply Voltage
+14.5...+15.5 V (max.70 mA)
-14.5...-15.5 V (max.65 mA)
operating voltage zero
The ripple on the supply voltage should not exceed 0.1 V peak‐to‐peak. The
supply connections are internally protected against reverse polarity. Single
sided connection of the supply voltage should be avoided. The supply voltage
should be kept as low as possible within the permissible range of
"15.6..."25 V in order to maintain the dissipation at a low value.
If a stabilized voltage is not available, the measuring amplifier can be operated
by means of a stabilized power supply or a DC‐DC converter (see chapter 7.1
and 7.2).
4.3
Output
Output voltage: "10 V; R
Operating voltage zero
The output is provided for the connection of a display and/or recorders. A cur
rent output can be generated optionally (see chapter 7.3).
10
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . . . . . . .
≥5 kΩ
. . . . . .
L
. . . . . . . . . . . . . . .
A00260_04_Y00_01 HBM: public
pin 15a
pin 16a
pin 19c
pin 18C
pin 20a
+
−
±
ME50S6