Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Welding - Abicor Binzel xFUME POWER 250 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7 Operation

7 Operation
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. This can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Only use the device in rooms with sufficient ventilation.
► Ensure that all seals on the device are free from dirt and debris.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Do not open the dust collecting drawer for at least one minute after the device is switched off.
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
Risk of injury due to fire
A fire may occur due to improper use or connection. They could cause major burns.
► Ensure that the operating voltage specified on the nameplate corresponds to the connection voltage.
► Do not use the device to extract welding fumes that result from welding oil-wetted parts.
► Do not use the device to extract flammable substances and liquids.
► Do not use the device in areas subject to dust or gas explosion hazards.

7.1 Welding

For optimal welding results, set the appropriate parameters for the voltage and wire feed speed as follows.
Set the necessary gas volume on the gas cylinder's pressure manometer.
EN - 22
WARNING
or a damp cloth.
WARNING
xFUME
Switch on the welding power source by pressing
1
the ON switch on the rear side.
 6.1 Connecting to the shielding gas supply on
page EN-16
 6.3.2 Installing the wire spool on page EN-19
Turn the control dial (Voltage) to set the welding
1
voltage.
Turn the control dial (Current) to set the wire feed
2
speed.
If necessary, use the control dial (Inductance) to
3
set the throttle.
Press the torch button to start the welding process.
4
In stand-by mode, the welding current can only be
set to a value of between 0 and 99. It is only
possible to precisely set the welding current while
welding.
®
POWER 250

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis