Minimum Cross-Sectional Area of Power and
Signal Cables (For reference)
Rated Current of Appliance (A)
>3 and ≤6
>6 and ≤10
>10 and ≤16
>16 and ≤25
>25 and ≤32
>32 and ≤40
b. Using wire strippers, strip the rubber jacket
from both ends of a signal cable to reveal
about 15cm (5.9") of the wires inside.
c. Strip the insulation from the ends of the
wires.
d. Using a wire crimper, crimp u-lugs on the
ends of the wires.
NOTE: While connecting the wires, strictly
follow the wiring diagram (found inside the
electrical box cover).
2. Remove the electric cover of the outdoor
unit. If there is no cover on the outdoor unit,
disassemble the bolts from the maintenance
board and remove the protection board.
3. Connect the u-lugs to the terminals
Match the wire colors/labels with the labels on
the terminal block and firmly screw the u-lug of
each wire to its corresponding terminal.
4. Clamp down the cable with the designated
cable clamp.
5. Insulate unused wires with electrical tape. Keep
them away from any electrical or metal parts.
6. Reinstall the cover of the electric control box.

Indoor Unit Wiring

1. Prepare the cable for connection
a. Using wire strippers, strip the rubber jacket
from both ends of a signal cable to reveal
about 15cm (5.9") of the wires inside.
b. Strip the insulation from the ends of the
wires.
◄ Page 28 ►
Nominal Cross-Sectional
Area (mm
)
2
0.75
1
1.5
2.5
4
6
Cover
Screw
c. Using a wire crimper, crimp the u-lugs to the
ends of the wires.
2. Pull the left and right handles of the front panel,
pull the panel outward, and open the panel.
3. Thread the power cable and the signal cable
through the wire outlet.
4. Connect the u-lugs to the terminals.
Match the wire colors/labels with the labels on
the terminal block and firmly screw the u-lug of
each wire to its corresponding terminal. Refer to
the Serial Number and Wiring Diagram located
on the cover of the electric control box.
This wires is just
for test.Please remove
while installation.
NOTE: When taking out the electric control
box, pay attention to loosen and remove the
terminal.
Magnetic ring (if supplied and packed with the
accessories)
Electric control box
Wiring diagram
Pass the belt through
the hole of the Mag-
netic ring to fix it on
the cable