Instructions for installation and use
2.2. Safety information for the installer
● Installation may only be performed by a qualified electrician or
similarly qualified person.
● Work on the sauna controller may only be performed when the
power has been disconnected.
● A fully disconnecting all-pole isolating device compliant with
overvoltage category III must be fitted on site.
● The sauna control unit must be installed outside the sauna room
at a height of approx. 1.70 m or in accordance with the rec-
ommendation issued by the sauna manufacturer. The ambient
temperature must be within a range spanning -10 °C to +40 °C.
● The heater sensor must be installed in such a way that it is not
affected by inflowing air.
● The heater supply cable must have a minimum cross-sectional
area of 2.5 mm
● Also comply with the regulations applicable at the installation
location.
● For your own safety, consult your supplier in the event of prob-
lems that are not explained in sufficient detail in the installation
instructions.
2
and be temperature-resistant up to 150 °C.
p. 7/60
EN