Herunterladen Inhalt Inhalt Diese Seite drucken

Activating Standby For Remote Operation - Sentiotec home.com4 Montage- Und Gebrauchsanweisungen

Saunasteuerung mit rs485-schnittstelle
Vorschau ausblenden Andere Handbücher für home.com4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 62
Instructions for use for the user
Intensity regulation when the dimmer switch function is deactivated
When the dimmer switch function for the additional output has been
deactivated, you can only switch the additional device on and off.
The unit will always operate at full power.
● Use rotary selector 1 to select the additional output icon. Then press
briefly to switch the additional output on or off.
► The additional output icon appears in the notification area of
the display.

10.16. Activating standby for remote operation

EN 60335-2-53 specifies that sauna control units with a remote start
function must be set manually to "Standby for remote operation" mode.
This activation must take place again after each remote start and stop
procedure.
Starting standby for remote operation:
● Use rotary selector 1 to select the remote start icon. Then press it
briefly to start the operating mode "Standby for remote operation".
► The sauna control unit switches off all previously activated func-
tions and the remote start icon appears on the display.
► The sauna control unit is then ready to be started and stopped
using a remote start signal. It is not possible to manually operate
the sauna control unit at the same time.
► After a remote start and stop, the remote start icon goes out and
the mode has to be activated again.
Cancelling standby for remote operation:
● To deactivate standby for remote control, press rotary selector 1
and at the same time turn it to the right.
p. 48/60

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Home.com4 black rs485Home.com4 white rs4851-052-984Hc4-b-rs4851-052-985Hc4-w-rs485

Inhaltsverzeichnis