Installation instructions, only for experts
COLLAXX (HUE VALUE SATURATION, 8-bit)
● Start address: Channel 49
► Channel light group 1:
► Channel light group 2:
► Channel light group 3:
► Channel light group 4:
HSV (HUE SATURATION VALUE, 8-bit)
● Start address: Channel 61
► Channel light group 1:
► Channel light group 2:
► Channel light group 3:
► Channel light group 4:
5.14. BUS connection (RS485 interface)
1. Guide the RJ45 data cables through cable gland 1 into the low-voltage
connection area.
2. Connect the data cable to the RJ45 socket i.
3. Observe the operating instructions and safety instructions for the respective
device (RS485 connection, MySentio WIFI, etc.)
5.15. Finishing the installation
1. Connect the earth conductor for the power supply cable and all devices to
the earth bar b.
2. Place the housing cover on the upper edge and connect the ribbon cable to
the lower part of the housing.
3. Press the upper part of the housing downwards and screw in the housing
screw with a screwdriver.
4. Finally, insert the two buttons (on/off switch and light switch) into the upper
part of the housing until they audibly click into place.