Herunterladen Inhalt Inhalt Diese Seite drucken

Engine Stop Switch; Thermo Switch - Yamaha WaveRunner XLT800 Wartungshandbuch

Vorschau ausblenden Andere Handbücher für WaveRunner XLT800:
Inhaltsverzeichnis

Werbung

+
ELEC
IGNITION SYSTEM
2. Measure:
G
Secondary coil resistance
Out of specification → Replace.
Secondary coil resistance:
Spark plug cap – Spark plug cap
14.3–30.5 kΩ at 20 ˚C (68 ˚F)

ENGINE STOP SWITCH

1. Check:
Engine stop switch continuity
G
Out of specification → Replace.
Engine stop switch continuity
(black coupler)
Lock plate
Position
Installed
Removed

THERMO SWITCH

1. Measure:
Thermo switch continuity
G
Out of specification → Replace.
Thermo switch continuity
temperature:
Pink (P) – Black (B)
a 80 ˚C (177 ˚F)
b 70 ˚C (159 ˚F)
1 No continuity
2 Continuity
Measurement steps:
Suspend the thermostat in a container
G
filled with water.
Place a thermometer in the water.
G
G
Slowly heat the water.
Measure the continuity when the spec-
G
ified temperature is reached.
7-15
Lead color
White
Free
Push
Free
Push
Å Temperature
ı Time
E
Black

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis