BNI CIP-351-000-K015
Safe I/O Module, EtherNet/IP™ CIP Safety™
IP67 Module
6.6.
I/O wiring
The following table shows different safety I/O wiring with their corresponding safety categories:
Safety Input wirings
Single Channel
Pulse test
Device
from Test
Output
Push
Yes
Button
TP0 is
configured as
24 V power
supply with
pulse test
No
TP0 is
configured as
24 V power
supply
www.balluff.com
M12 Port Wiring
1
2
TP1
IN1
TP0
1
5
GND
IN0
3
4
24 VDC
Dry Contact
1
2
TP1
IN1
TP0
1
5
GND
IN0
3
4
24 VDC
Dry Contact
Safety
Category
2
1
64