BNI CIP-351-000-K015
Safe I/O Module, EtherNet/IP™ CIP Safety™
IP67 Module
Listen Only
This connection type is identical to an Input Only connection type, with a single exception: a Listen Only
connection can only exist when one of the other I/O connection (EO) types has been established. That is, a
Listen Only connection cannot be established until an Input/Output or Input Only connection has been
established, and conversely when the last non-Listen-Only connection has been closed or has timed out, the
Listen Only connection will automatically close as well. This connection type is the least-frequently used type.
Note!
Upload EDS file from the safety module
Input Assembly
Output Assembly (Heartbeat)
Configuration Assembly
www.balluff.com
to easily configure the connection.
768 (300 Hex), Size 13 bytes
199 (C7 Hex), Size 0 bytes
103 (67 Hex), size 0 byte
45