K5+ – Maintenance and do-it-yourself
A new main fuse is available as spare part from
customer service.
1. Switch off the machine at the main power switch.
2. Remove the power cord from the connection
panel.
3. Remove the cover of the fuse.
F
. 65 C
(
IG
OVER OF THE FUSE
MARKED ORANGE
4. Remove the defective fuse and replace it with a
new fuse.
5. If you do not have a replacement fuse ready, take
the replacement fuse from the right side of the fuse
cover and put it into the left side of the fuse cover.
6. Remount the fuse cover.
)
Original Operating Instructions:  K5+
Version: 12/16/2021

8.11 Calibrating the axes

Deterioration of machining
NOTICE
results caused by an incorrect
calibration
At delivery, your machine is already calibrated. As long
as your machining results are accurate, a new calib-
ration is not necessary. A calibration takes much time
and will deteriorate the machining results if it is
improperly executed.
In case of inaccurate machining results, try adjusting
the machining conditions first: Check the fixation
and quality of the blank and the state of the tool.
Before calibrating the machine, contact customer
service.
Be very careful when measuring and entering data
during calibration. When in doubt, abort the cal-
ibration.
By calibrating the machine with test and calibration
specimens, it may be possible to improve the
machining results.
The documentation for the manufacturing soft-
ware contains all information on calibrating the
machine. Therefore, you will only find inform-
ation specific to this machine in this document.
Your machine is delivered with a calibration set. It
contains the following parts:
Calibration blanks which are used to mill cal-
n
ibration and test specimens
A tool for milling the calibration or test specimens
n
A micrometer for measuring the machining pre-
n
cision
You can calibrate the machine as follows:
1. Have the calibration set readily available.
2. Mount the calibration blank into the blank holder.
3. Follow the instructions on calibrating the machine
in the documentation for DENTALCNC.
4. Keep all parts of the calibration set except used cal-
ibration blanks for further use.
EN 47