K5+ – Installing the machine

5.6 Installing the pneumatics

Risk of injuries through
WARNING
leaking compressed air and
lashing pneumatic hoses
Open or loose pneumatic connections can cause
severe injuries.
Ensure that during installation and maintenance
of the pneumatic hoses and of the compressed air
regulator compressed air is not conducted through
the hoses and connections.
Before conducting compressed air through the
hoses and connectors, verify that the hoses are
securely inserted into the correct connectors and
that they are not damaged. This also applies to the
compressed air regulator.
Do not conduct compressed air through damaged
hoses and connectors.
The spindle may suffer
NOTICE
bearing damage and electrical
damage if the compressed air is contaminated
The incoming compressed air must be dry and oil-free
according to ISO 8573-1:2010 because the
compressed air regulator only serves as an indicator
for contaminated air.
Air purity according to ISO 8573-1:2010
Solid
class 3
Filtration degree better than 5 µm
particles
for solid particles
Water
class 4
Maximum pressure dew point
content
+3 °C
Residual oil
class 3
Maximum oil content: 1 mg/m
content
Ensure that the compressed air meets the above
requirements.
Only connect the machine to the compressed air
supply if the compressed air regulator is properly
installed.
Connect the machine to the compressed air supply
only via the provided compressed air regulator.
You can find specific values and additional require-
ments in the chapter on technical data.
data – on page  14
The machine requires the compressed air for the
following tasks:
For the opening and closing of the collet chuck
n
during tool changes.
3
Technical
Original Operating Instructions:  K5+
Version: 12/16/2021
For the spindle sealing air which prevents foreign
n
bodies from entering the spindle.
For the sealing air in the working chamber that
n
keeps machining debris away from sensitive
machine parts.
For the ionizer.
n
EN 19