Operating manual
pneuMATO-fill
5
Set up and operation (mobile)
-
Remove cover from grease bucket.
-
Press the grease follower piston onto the grease in the bucket, until it is visible in the central
opening. The rubber lip must lie evenly against the bucket wall.
-
Lay the dust protection cover on the bucket with the grease sequence cover and centre with the
wing screws.
-
Push the pumping station support down until you reach the dust protection cover and secure with
a wing nut.
-
Push the pumping station through the pumping station support, the dust protection cover and the
grease sequence cover until it reaches the grease container base. Secure pumping station with
wing nut.
-
Connect high pressure reinforced rubber hose with grease gun to the pumping station.
-
Check all connections for a firm fit and leaks before starting the system.
-
Connect air connection to the air pump and ensure that no more than 8 bar of air pressure
at the pump is pending. Once the air supply is established, the pump independently sucks in the
lubricating grease.
-
The use of an automatic nozzle is of advantage for proper venting during commissioning of the
pump system, if the hose connection is opened slightly at the pump during the intake process
(max. ½ revolution). The air trapped in the pump system can then escape easily.
-
As soon as the grease is sucked in - switch off the pump and tighten hose connection.
-
The pump will automatically shut off when stopcock is closed after reaching the maximum
operating pressure and is ready for use.
-
When the system is not in use turn off the air supply to the pump.
Observe safety instructions.
6
Maintenance and care:
Maintenance, inspection and repair work must only be performed by qualified personnel.
The air link is to be removed before any repair or maintenance work, and after each use,
furthermore grease pressure on the delivery hose is to be relieved by pressing the trigger lever
on the grease gun.
Regularly check the pressure-bearing components (high pressure hose) for any damage or
wear. Defective parts must be replaced immediately with genuine parts.
Ordering spare parts:
When ordering spare parts the following information is required:
Type specification, designation of the ET, order number.
Request the appropriate spare parts list if necessary.
The following maintenance periods should be strictly observed to ensure trouble-free operation.
Pressure hose
Checking for loose
connections
Legibility and availability of
information
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120
GmbH & Co. KG
MATO
Before each use
X
X
Annually
Observe
manufacturer's
information and the
hazard assessment
of the operator.
X
X
X