C60_2-028_823024_0401-e.p65
65
Mounting the
BIS C-6022
processor
66
Opening the
BIS C-6022
processor
BIS C-6022
interfaces
Connection locations
and names
66
E
BIS C-6022
Mounting Processor
The processor is mounted using 4 M4 screws.
X1
X2
X3
ca. 20
60
BIS C-6022
Opening the processor / Interface information
To set the PROFIBUS-DP address, activate or deactivate the internal termination resistor, set
the compatibility mode or to change the EEPROM, you must open up the BIS C-6022 proces-
sor.
Remove the 4 screws on the BIS C-6022 and lift off the cover. See the following
tional information.
Connection for read/write head 2
Supply voltage,
X1
input/output
PROFIBUS-DP
X2
output
PROFIBUS-DP
X3
input
Service interface
Head 2 Head 1
M4
X4
63
100
Head 2 Head 1
Connection for read/write head 1
Be sure before
opening that the unit
is disconnected
from power.
Mounting of the cover
(4 screws),
max. permissible tightening
torque: 0.15 Nm
X4
Protection ground PE
E
65