C60_2-028_823024_0401-e.p65
47
Read times from
data carrier to
processor in
dynamic mode
(parametering:
2nd byte, bit 5 = 1)
48
Function displays
on BIS C-60_2
48
E
Read/Write Times
Read times within the 1st block for dual read and compare:
The indicated times apply after the data carrier has been recognized. If the data carrier is not
yet recognized, an additional 45 ms for building the required energy field until the data carrier is
recognized must be added.
m = highest address to be read
Formula: t = (m + 1) * 3.5 ms
Example: Read 11 bytes starting at address 9, i.e. the highest address to be read is 19.
This corresponds to 70 ms.

LED Display

The BIS C-60_2 uses the three side-mounted LED's to indicate important conditions of the
identification system.
Status
LED
Ready / Bus active
red
green
CT1 Present / operating
green
yellow
yellow flashes Cable break to read/write head or not connected.
off
CT2 Present / operating
green
yellow
yellow flashes Cable break to read/write head or not connected.
off
If all three LED's are synchronously flashing, it means a hardware error. Return the unit to the factory.
Meaning
Supply voltage OK; no hardware error,
however, bus not active.
Supply voltage / hardware OK,
bus active.
Data carrier read/write-ready at read/write head 1.
Read/write command at read/write head 1 in
process.
No data carrier in read/write range of
read/write head 1.
Data carrier read/write-ready at read/write head 2.
Read/write command at read/write head 2 in
process.
No data carrier in read/write range of
read/write head 2.
E